Technical data - OPTImess MLC
Typ | OMS 4620 | OMS 4630 | OMS 4640 | OMS 4650 | OMS 4660 | OMS 4680 | OMS 4700 | OMS 4720 | OMS 4760 |
---|---|---|---|---|---|---|---|---|---|
Measuring range [mm] | 200 | 300 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1600 |
Stand off [mm] | 200 | 400 | 500 | 600 | 800 | 1000 | 1200 | 1500 | 2000 |
Resolution [mm]* | 0.02 | 0.03 | 0.04 | 0.05 | 0.06 | 0.08 | 0.1 | 0.15 | 0.2 |
Linearity | ≤ 0.06% of range |
Reproductibility | ≤ 0.03% of range |
Bandwidth | 50kHz max. |
Ambient light | > 100,000 lux (sunlight) |
shock | 15G/6ms, EN 60068 |
Environment, Security | EN 50155 |
Approvals | CE |
Humidity | 5% - 95%, non-condensing |
Wavelength [nm] | 405–850nm, depending on application |
Laser class | 1/2/3R/3B |
Supply voltage | 10-32 V DC |
Output signal | ±5V / ±10V, 0-5V, 0-10V / 0-20mA / 4-20mA / CAN bus |
Temperature range | -20°C to 60°C (optionally extendable to -40°C) |
Dimensions | 160 x 117 x 45 mm |
Weight | approx. 1.1kg |
Protection class | IP67 (even when unplugged) |
[*] Measuring rate ≤ 10 kHz