Technical data - OPTImess MLC

Typ | OMS 8008 | OMS 8020 | OMS 8040 | OMS 8080 | OMS 8120 | OMS 8200 |
---|---|---|---|---|---|---|
Measuring range [3] | 8 | 20 | 40 | 80 | 120 | 200 |
Stand off [3] | 50 | 100 | 150 | 200 | 300 | 400 |
Resolution | 0.002 | 0.005 | 0.01 | 0.02 | 0.03 | 0.050 |
Linearity | ≤ 0.06% of range |
Reproductibility | ≤ 0.03% of range |
Bandwidth | 20kHz max. |
Filter | Digital averaging |
Measuring rate | 20kHz max. |
Light source | Laser diode |
Spot diameter | 0.05 - 5 mm |
Wave length | 660–780 nm |
Laser safety class | 2 / 3R / 3B |
Photo detector | CMOS linear image sensor |
Supply voltage | ± 15V / 120mA, ±5% or10-30 V |
Output | ±5V / ±10V, 0-10V / 0-20mA / 4-20mA / CAN-Bus |
Operating temerature | -20°C up to 50°C no condensation |
Dimensions | 160 x 117 x 40 mm |
Weight | app. 820 g |
Protection class | IP65 (without protective glass IP54) |
[1] Standard settings with filter 200Hz [2] Factory-set depending on the application [3] Other types upon request [4] only unipolar output and CAN Bus