Technical Data - OPTImess MC

Typ | OMS 4104 | OMS 4108 | OMS 4110 | OMS 4120 | OMS 4122 | OMS 4123 | OMS 4132 | OMS 4140 | OMS 4141 |
---|---|---|---|---|---|---|---|---|---|
Measuring range [3] | 40 | 80 | 100 | 200 | 200 | 200 | 300 | 400 | 400 |
Stand off [3] | 60 | 70 | 80 | 150 | 300 | 340 | 400 | 300 | 400 |
Resolution | 0.02 | 0.03 | 0.04 | 0.06 | 0.1 | 0.1 | 0.1 | 0.1 | 0.15 |
Linearity | ≤ 0.3% of range |
Reproductibility | ≤ 0.1% of range |
Max. measurement rate | 4 kHz |
Dimensions | 65 x 50 x 20 mm |
Weight | 95g |
Humidity | 5% - 95%, non-condensing |
Protection type | IP67 (also when unplugged) |
Ambient light | over 100.000 lux (sunlight) |
Vibration | 10-100 Hz, 2mm |
Shock | 15G / 6ms, EN 60068 |
Temperature range | -20°C to 60°C |
Environment, safety | EN 50155 |
Certifications | CE |
Protection class | 2, 3R |
Wavelength | 660 nm |
Supply voltage | 12 - 32 V DC |
Power | 2 W |
Interface | 0-5V / 0-10V / CAN Bus |
[1] Standard settings with filter 200Hz [2] Factory-set depending on the application [3] Other types upon request