Lasermesstechnik

Laser measurement

Technical data - OPTImess MLC

Typ OMS 4620 OMS 4630 OMS 4640 OMS 4650 OMS 4660 OMS 4680 OMS 4700 OMS 4720 OMS 4760
Measuring range [mm] 200 300 400 500 600 800 1000 1200 1600
Stand off [mm] 200 400 500 600 800 1000 1200 1500 2000
Resolution [mm]* 0.02 0.03 0.04 0.05 0.06 0.08 0.1 0.15 0.2
Linearity ≤ 0.06 % of range
Reproductibility ≤ 0.03 % of range
Bandwidth 50 kHz max.
Ambient light > 100,000 lux (sunlight)
shock 15G/6 ms, EN 60068
Environment, Security EN 50155
Approvals CE
Humidity 5 % - 95 %, non-condensing
Wavelength [nm] 405–850 nm, depending on application
Laser class 1 / 2 / 3R / 3B
Supply voltage 10-32 V DC
Output signal ± 5 V / ±10 V, 0-5 V, 0-10 V / 0-20 mA / 4-20 mA / CAN bus
Temperature range -20 °C to 60 °C (optionally extendable to -40 °C)
Dimensions 160 x 117 x 45 mm
Weight approx. 1.1 kg
Protection class IP67 (even when unplugged)

[*] Measuring rate ≤ 10 kHz