Technical data - OPTImess 2D-HLS

Basic types | 2025 | 3025 | 3016 | 4025 | 4016 | 6025 | 6016 | 20012 | Unit |
---|---|---|---|---|---|---|---|---|---|
Measuring field start | 160 | 240 | 210 | 300 | 300 | 450 | 400 | 1800 | mm |
Measuring field end | 240 | 360 | 390 | 500 | 600 | 750 | 1000 | 2500 | mm |
Line length start | 92 | 130 | 175 | 145 | 220 | 210 | 330 | 1580 | mm |
Line length end | 120 | 175 | 275 | 235 | 400 | 330 | 700 | 1960 | mm |
Line resolution | 45 -60 | 65 - 85 | 85 - 135 | 71 - 115 | 110 - 200 | 105 - 165 | 165 - 350 | 800 - 1000 | µm |
Standard deviation | 8 | 10 | 20-25 | 25 - 35 | 30 - 40 | 60 | 120 | 600 | µm |
Length | 250 | 300 | 300 | 300 | 300 | 300 | 300 | 450 | mm |
Width | 140 | 140 | 140 | 140 | 140 | 140 | 140 | 124 | mm |
Thickness | 60 | 60 | 60 | 60 | 60 | 60 | 60 | mm | |
Weight | 2.2 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 3.0 | kg |
Humidity | 5% - 95%, non-condensing |
Protection rating | IP67 (even when unplugged) |
Ambient light | > 100.000 Lux (Sonnenlicht) |
Vibration | 10 - 100 Hz, 2 mm |
Shock | 15 G / 6 ms, EN 60068 |
temperature range | -20°C bis 50°C |
EMV | EN 6100-6-2, EN 6100-6-4, EN 50121-3-2 |
Approvals | CE |
Class | 2, 3R , 3B |
Supply voltage | 10 - 32 V DC |
Interface | Ethernet 100/1000BASE-T |