Lasermesstechnik

Laser measurement

Technical data - OPTImess MR

Type OMS 7505 OMS 7510 OMS 7520 OMS 7540 OMS 7560 OMS 7580
Measuring range [3] 50 100 200 400 600 800
Stand off [3] 200 300 400 800 1000 1200
Resolution 0.010 0.025 0.050 0.100 0.150 0.200
Linearity ≤ ± 0.06 % of range
Reproductibility ≤ ± 0.03 % of range
Bandwidth [2] 20 kHz max.
Filter [2] Digital averaging
Measuring rate [2] 20 kHz
Light source Laser diode
Spot diameter [2] 0.05 - 5 mm
Wave-length [2] 660–780 nm
Laser safety class [2] 2 / 3R / 3B
Photo detector CMOS linear image sensor
Supply voltage ± 15 V / 120 mA, ± 5 % or 12-30 V / 120 mA [4]
Output [2] ± 5 V / ± 10 V, optional: 0-5 V / 0-10 V / 0-20 mA / 4-20 mA / CAN bus
Operating temerature -20 °C up to 50 °C no condensation
Dimensions 200 x 160 x 60 mm
Weight app. 2.700 g
Protection class IP65